Corrosion Testing
Passivation confirmation test
Ferroxyl test - contamination detection
Ferroxyl Test – Contamination test
![]() |
LMATS is NATA accredited to perform Ferroxyl test in accordance with ASTM A380 and ASTM A967. This test is a highly sensitive test and should be performed when no traces of free iron or iron oxide is acceptable on the Passivated items. The test can be used on stainless steel to detect iron contamination, including iron-tool marks, residual-iron salts from pickling solutions, iron dust, iron deposits in welds, embedded iron or iron oxide, etc. Due to the use of Potassium Ferricynide this test method cannot be employed in the food industry. Contact LMATS Melbourne or Sydney laboratory staff for your ferroxyl test or contamination detection test or corrosion resistance test. |