Corrosion Testing
Passivation confirmation test
High Humidity test
High Humidity Test
This test is used for the detection of free iron or any other anodic surface contaminants on stainless steel. The test is performed in a humidity cabinet capable of maintaining 97±3% humidity 38%±3°C for a minimum of 24 hours. The test sample is acceptable if there is no evidence of rust stains or other corrosion products after completion of the test. High Humidity test is performed in accordance with ASTM A380 and ASTM A967.
Talk to LMATS Melbourne or Sydney laboratory staff for your high humidity test requirements.
- Mechanical Testing
- Spectroscopy
- Chemical Testing
- Corrosion Testing
- Weld Qualification
- Metallurgical Services
- Hydrostatic Test
- Engineering structures test
- Engineering Inspections
- Non Destructive Testing
- Protective Coatings test
- Calibration Services
- Professional Services
- Tests on Concrete & Refractory material
- Hand Tools Testing
- Abrasive Testing
- Miscellaneous Services
Melbourne Victoria Non Destructive Testing Services
Melbourne Head Office
6 Techno Park Drive
Williamstown,Vic 3016
Phone +61 03 9399 8145
Non Destructive Testing Services NDT Melbourne Victoria
Sydney NSW Non Destructive Testing Services
Sydney NSW
1C / 137 Silverwater Road,
Silverwater, NSW 2128
Phone 02 9648 1989
Non Destructive Testing Services NDT Sydney NSW